Five-year follow-up after transcatheter aortic valve implantation for symptomatic aortic stenosis

Heart. 2017 Dec;103(24):1970-1976. doi: 10.1136/heartjnl-2016-311004. Epub 2017 Jul 6.

Abstract

Objectives: Transcatheter aortic valve implantation (TAVI) has been implemented into the care of elderly patients suffering from severe symptomatic aortic stenosis. However, data on long-term follow-up are sparse and predictors of long-term mortality need to be evaluated to better select patients. Therefore, we aimed to analyse predictors of 5-year mortality after TAVI.

Methods: We analysed data from the German Transcatheter Aortic Valve Interventions-Registry. Each of the 27 participating hospitals agreed to include all consecutive TAVI patients at their institution. Out of 1444 patients treated with TAVI, 1378 patients had a follow-up of at least 4.5 years (completeness 95.4%). Endpoint for this analysis was 5-year survival. Cox regression analysis was used to determine risk factors associated with this endpoint.

Results: Patients who died were compared with survivors. The two groups showed multiple differences in patient characteristics, indications for interventions, preinterventional, as well as interventional characteristics and postinterventional events. Calculated 1-year mortality was 21.8% and 5-year mortality 59.1%. A higher logistic EuroScore was associated with a lower 5-year survival, being 45.5% in patients with a logistic EuroScore of <20%, 34.5% in those with 20% to 40% and 28.4% in patients with a logistic EuroScore >40%. Cox proportional hazard analysis revealed the following independent predictors of 5-year mortality: female gender (HR =0.66, 95% CI 0.56 to 0.77, p<0.0001), renal failure (HR=1.43, 95% CI 1.22 to 1.69, p<0.0001), prior mitral regurgitation ≥II° (HR=1.42, 95% CI 1.21 to 1.65, p<0.0001), residual aortic regurgitation ≥II° (HR=1.52, 95% CI 1.24 to 1.85, p<0.0001), atrial fibrillation (HR=1.38, 95% CI 1.18 to 1.64, p=0.0001), low gradient aortic stenosis (HR=1.48, 95% CI 1.19 to 1.84, p=0.0004), prior decompensation (HR=1.32, 95% CI 1.13 to 1.54, p=0.0006), frailty (HR=1.31, 95% CI 1.09 to 1.58, p=0.004), surgical TAVI (HR=1.42, 95% CI 1.12 to 1.80, p=0.004), age (by year) (HR=1.02, 95% CI 1.01 to 1.03, p=0.006), prior myocardial infarction (HR=1.29, 95% CI 1.07 to 1.57, p=0.009), urgent TAVI (HR=1.25, 95% CI 1.04 to 51, p=0.020) and diabetes mellitus (HR=1.20, 95% CI 1.02 to 1.40, p=0.024).

Conclusions: These data from the early TAVI experience show a 5-year mortality of 59.1%. Some of the predictors of 5-year mortality seem to be modifiable, such as residual aortic regurgitation, type of TAVI access route and concomitant mitral regurgitation.

Keywords: endovascular procedures for aortic and vascular disease; transcatheter valve interventions.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Stenosis / complications
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Female
  • Germany
  • Heart Valve Prosthesis
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Mitral Valve Insufficiency / complications
  • Mitral Valve Insufficiency / physiopathology
  • Multivariate Analysis
  • Proportional Hazards Models
  • Prosthesis Design
  • Registries
  • Risk Factors
  • Time Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Transcatheter Aortic Valve Replacement* / mortality
  • Treatment Outcome