The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report

Eur J Cardiothorac Surg. 2018 Feb 1;53(2):309-316. doi: 10.1093/ejcts/ezx320.

Abstract

Objectives: The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports.

Methods: Participating hospitals contributed surgical and cardiological pre-, peri- and long-term postoperative data of mechanical circulatory support implants to the registry. Data for all implants performed from 1 January 2011 to 31 December 2016 were analysed. Several auditing methods were used to monitor the quality of the data. Data could be provided for in-depth studies, and custom data could be provided at the request of clinicians and scientists. This report includes updates of patient characteristics, implant frequency, mortality rates and adverse events.

Results: Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (>17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66-71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0-70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation.

Conclusions: Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.

Keywords: End-stage heart failure; Mechanical circulatory support; Registry; Ventricular assist device.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Child
  • Child, Preschool
  • Cohort Studies
  • Female
  • Heart Failure* / mortality
  • Heart Failure* / surgery
  • Heart, Artificial*
  • Humans
  • Infant
  • Infant, Newborn
  • Male
  • Middle Aged
  • Registries*
  • Thoracic Surgical Procedures* / adverse effects
  • Thoracic Surgical Procedures* / instrumentation
  • Thoracic Surgical Procedures* / methods
  • Thoracic Surgical Procedures* / mortality
  • Young Adult