Comparison of ferumoxytol-based cerebral blood volume estimates using quantitative R1 and R2* relaxometry

Magn Reson Med. 2018 Jun;79(6):3072-3081. doi: 10.1002/mrm.26975. Epub 2017 Nov 2.

Abstract

Purpose: Cerebral perfusion is commonly assessed clinically with dynamic susceptibility contrast MRI using a bolus injection of gadolinium-based contrast agents, resulting in semi-quantitative values of cerebral blood volume (CBV). Steady-state imaging with ferumoxytol allows estimation of CBV with the potential for higher precision and accuracy. Prior CBV studies have focused on the signal disrupting T2* effects, but ferumoxytol also has high signal-enhancing T1 relaxivity. The purpose of this study was to investigate and compare CBV estimation using T1 and T2*, with the goal of understanding the contrast mechanisms and quantitative differences.

Methods: Changes in R1 (1/T1 ) and R2* (1/ T2*) were measured after the administration of ferumoxytol using high-resolution quantitative approaches. Images were acquired at 3.0T and R1 was estimated from an ultrashort echo time variable flip angle approach, while R2* was estimated from a multiple gradient echo sequence. Twenty healthy volunteers were imaged at two doses. CBV was derived and compared from relaxometry in gray and white matter using different approaches.

Results: R1 measurements showed a linear dependence of blood R1 with respect to dose in large vessels, in contrast to the nonlinear dose-dependence of blood R2* estimates. In the brain parenchyma, R2* showed linear dose-dependency whereas R1 showed nonlinearity. CBV calculations based on R2* changes in tissue and ferumoxytol blood concentration estimates based on R1 relaxivity showed the lowest variability in our cohort.

Conclusions: CBV measurements were successfully derived using a combined approach of R1 and R2* relaxometry. Magn Reson Med 79:3072-3081, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Keywords: R2*; R1; cerebral blood volume; ferumoxytol; gray matter; white matter.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Blood Volume
  • Brain / diagnostic imaging
  • Cerebral Blood Volume / physiology*
  • Cerebrovascular Circulation*
  • Contrast Media / administration & dosage
  • Female
  • Ferrosoferric Oxide / administration & dosage*
  • Gadolinium / administration & dosage
  • Hemodynamics
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Least-Squares Analysis
  • Magnetic Resonance Imaging*
  • Male
  • Middle Aged
  • Perfusion
  • Reproducibility of Results
  • White Matter / diagnostic imaging
  • Young Adult

Substances

  • Contrast Media
  • Gadolinium
  • Ferrosoferric Oxide