A practical method of I-131 thyroid cancer therapy dose optimization using estimated effective renal clearance

SAGE Open Med Case Rep. 2017 Dec 7:5:2050313X17745203. doi: 10.1177/2050313X17745203. eCollection 2017.

Abstract

In thyroid cancer patients with renal impairment or other complicating factors, it is important to maximize I-131 therapy efficacy while minimizing bone marrow and lung damage. We developed a web-based calculator based on a modified Benua and Leeper method to calculate the maximum I-131 dose to reduce the risk of these toxicities, based on the effective renal clearance of I-123 as measured from two whole-body I-123 scans, performed at 0 and 24 h post-administration.

Keywords: I-123; I-131; Thyroid cancer; dosimetry; radioiodine; radionuclide therapy.

Publication types

  • Case Reports