Abstract

Background: Paravalvular aortic regurgitation (PVAR) remains a frequent postprocedural concern following transcatheter aortic valve replacement (TAVR). Persistence of flow turbulence results in the cleavage of high-molecular-weight von Willebrand multimers, primary haemostasis dysfunction and may favour bleedings. Recent data have emphasized the value of a point-of-care measure of von Willebrand factor-dependent platelet function (closure time [CT] adenosine diphosphate [ADP]) in the monitoring of immediate PVAR. This study examined whether CT-ADP could detect PVAR at 30 days and bleeding complications following TAVR.

Methods: CT-ADP was assessed at baseline and the day after the procedure. At 30 days, significant PVAR was defined as a circumferential extent of regurgitation more than 10% by transthoracic echocardiography. Events at follow-up were assessed according to the Valve Academic Research Consortium-2 consensus classification.

Results: Significant PVAR was diagnosed in 44 out of 219 patients (20.1%). Important reduction of CT-ADP could be found in patients without PVAR, contrasting with the lack of CT-ADP improvement in significant PVAR patients. By multivariate analysis, CT-ADP > 180 seconds (hazard ratio [HR]: 5.1, 95% confidence interval [CI]: 2.5-10.6; p < 0.001) and a self-expandable valve were the sole independent predictors of 30-day PVAR. At follow-up, postprocedural CT-ADP >180 seconds was identified as an independent predictor of major/life-threatening bleeding (HR: 1.7, 95% CI [1.0-3.1]; p = 0.049). Major/life-threatening bleedings were at their highest levels in patients with postprocedural CT-ADP > 180 seconds (35.2 vs. 18.8%; p = 0.013).

Conclusion: Postprocedural CT-ADP > 180 seconds is an independent predictor of significant PVAR 30 days after TAVR and may independently contribute to major/life-threatening bleedings.

MeSH terms

  • Adenosine Diphosphate / blood*
  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / blood
  • Aortic Valve Insufficiency / diagnosis*
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Stenosis / blood
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Blood Platelets / metabolism*
  • Echocardiography, Doppler
  • Female
  • Heart Valve Prosthesis
  • Humans
  • Male
  • Platelet Aggregation*
  • Platelet Function Tests / methods*
  • Point-of-Care Testing*
  • Postoperative Hemorrhage / blood
  • Postoperative Hemorrhage / diagnosis*
  • Postoperative Hemorrhage / etiology
  • Predictive Value of Tests
  • Prosthesis Design
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects*
  • Transcatheter Aortic Valve Replacement / instrumentation
  • Treatment Outcome
  • von Willebrand Factor / metabolism

Substances

  • von Willebrand Factor
  • Adenosine Diphosphate