A modified two-point titration method for the determination of volatile fatty acids in anaerobic systems

Chemosphere. 2018 Aug:204:251-256. doi: 10.1016/j.chemosphere.2018.04.038. Epub 2018 Apr 10.

Abstract

The volatile fatty acids (VFA) concentration plays important roles in the rapid start-up and stable operation of anaerobic reactors. It's essential to develop a simple and accurate method to monitor the VFA concentration in the anaerobic systems. In present work, a modified two-point titration method was developed to determine the VFA concentration. The results show that VFA concentration in standard solutions estimated by the titration method coincided well with that measured by gas chromatograph, where all relative errors were lower than 5.5%. Compared with the phosphate, ammonium and sulfide subsystems, the effect of bicarbonate on the accuracy of the developed method was relatively significant. When the bicarbonate concentration varied from 0 to 8 mmol/L, the relative errors increased from 1.2% to 30% for VFA concentration at 1 mmol/L, but were within 2.0% for that at 5 mmol/L. In addition, the VFA composition affected the accuracy of the titration method to some extent. This developed titration method was further proved to be effective with practical effluents from a lab-scale anaerobic reactor under organic shock loadings and an unstable full-scale anaerobic reactor.

Keywords: Anaerobic digestion; Two-point titration; Volatile fatty acids; Weak acid.

MeSH terms

  • Anaerobiosis
  • Bioreactors*
  • Chromatography, Gas
  • Fatty Acids, Volatile / analysis*
  • Fatty Acids, Volatile / chemistry*

Substances

  • Fatty Acids, Volatile