Purpose: To assess feasibility of producing intelligible and comprehensible speech with an electrolarynx; measure anxiety, communication ease, and satisfaction before/after electrolarynx training; and identify barriers/facilitators.
Methods: We included tracheostomized adults from 3 units following commands, reading English, and mouthing words. On enrolment, we measured anxiety, ease, and satisfaction with communication. We gave electrolarynx instruction for ≤5 days then 2 independent raters assessed intelligibility, sentence comprehensibility (9-point difficulty scale), and Electrolarynx Effectiveness Score (EES), and re-evaluated anxiety, communication ease, and satisfaction. Interviews explored barriers/facilitators.
Measurements and main results: We recruited 24 participants (Jan2015-Dec2016). Mean (SD) intelligibility was 45%(18%) words correct: 57%(21%) when facing. Mean comprehension difficulty was 6.4(2.0) overall, indicating moderate difficulty (5.5(2.5) scored visualizing). Mean EES was 2.9(1.0) (3 = improved lip-reading through recognizable sounds). Anxiety decreased from median 3.8 to 2.0 (P = .007). Communication was rated easier (median 15 vs 12, P = .04) whereas satisfaction remained similar (P = .06). Facilitators included device friendliness, patient independence, and word intelligibility. Barriers were patient weakness, difficulty positioning the device, and limited sentence as opposed to word intelligibility.
Conclusion: The electrolarynx may aid intelligible speech for some tracheostomized patients if the communication partner can visualize the users face, and reduce anxiety and make patient perceived communication easier.
Keywords: Alternative augmented communication; Communication tools; Electrolarynx; Intensive care; Speech; Tracheostomy.