Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016

Blood Press Monit. 2018 Dec;23(6):305-311. doi: 10.1097/MBP.0000000000000349.

Abstract

Background: Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC).

Objective: To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems.

Patients and methods: The 2011-2016 National Health and Nutrition Examination Survey, a cross-sectional survey, was used to estimate mean mid-AC (n=24 723).

Results: Mean mid-AC did not differ from 2011 to 2016 (31.0 vs. 31.3 cm, P>0.05). During 2011-2016, mean mid-AC was greater for males than females (32.0 vs. 30.4 cm, P<0.001) and was largest among adults 40-49 years (34.0 cm). Non-Hispanic Black persons had the largest mean mid-AC (32.0 cm) and non-Hispanic Asian persons the smallest (28.4 cm). Increased BMI was associated with increased mean mid-AC for those 3-19 years (normal, 22.0 cm and obese, 31.5 cm, P<0.001) and more than 20 years (normal, 28.2 cm and obese, 37.8 cm, P<0.001). Among those aged 8-17 years, high BP status was associated with a larger mean mid-AC (normotensive 26.1 cm vs. high BP 28.2 cm, P=0.001). Among adults aged 18 years and older, hypertension status was associated with a larger mean mid-AC (normotensive 32.4 cm vs. hypertensive 34.2 cm, P<0.001). Among those aged 12-19 years, 13.0% required a Baum large cuff (35-46.9 cm mid-AC) and 21.7% required a Welch Allyn large cuff (32-39.9 cm mid-AC). Among those aged more than 20 years, 33.2% required a Baum large cuff, 48.2% required a Welch Allyn large cuff, 1.3% required a Baum extra-large cuff (44-66 cm mid-AC), and 9.5% required a Welch Allyn extra-large cuff (40-55 cm mid-AC).

Conclusion: Currently, BP is obtained in clinic, pharmacy, home, and ambulatory setting using single or multiple cuffs. National Health and Nutrition Examination Survey mid-AC data should be considered for accurate cuffing avoiding cuff hypertension or hypotension.

Publication types

  • Clinical Trial

MeSH terms

  • Adolescent
  • Adult
  • Arm* / pathology
  • Arm* / physiopathology
  • Blood Pressure Monitors*
  • Blood Pressure*
  • Body Mass Index*
  • Child
  • Child, Preschool
  • Female
  • Humans
  • Hypertension* / pathology
  • Hypertension* / physiopathology
  • Male
  • Obesity* / pathology
  • Obesity* / physiopathology