[Determination of p-Anisidine in workplace air by HPLC]

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2018 Jun 20;36(6):468-471. doi: 10.3760/cma.j.issn.1001-9391.2018.06.023.
[Article in Chinese]

Abstract

Objective: To establish an HPLC method for determining p-Anisidine in workplace air. Methods: An C(18) capillary column was used with the detection wavelength of 240 nm, the methanol solution (v/v=62:38) as mobile phase, the flow rate was 0.9 ml/min, and the injection volume was 20 μl. Results: The linear range (μg/ml) for p-Anisidine was 0~100; correlation coefficient was 0.999 7; the detection limit was 0.15 μg/ml; the average precision of RSD was 4.4%. The sampling efficiency was more than 95% using silicone tube as sampling filter. Sample can be stored at room temperature for more than 7 d. Conclusion: the method appered to be accurate, simple, sensitive and reliable, also have a high sampling efficiency, and can be usd to determine p-anisidine in workplace air simultaneously.

目的: 建立工作场所空气中对氨基苯甲醚的高效液相色谱检测法。 方法: 采用高效液相色谱法,色谱柱为C(18)柱,流动相为甲醇:纯水=62:38(v/v),流速0.9 ml/min,检测波长240 nm,进样体积20 μl。 结果: 该方法测定对氨基苯甲醚线性范围(μg/ml)为0~100;相关系数(r)0.999 7;最低检出限为0.15 μg/ml;平均精密度RSD为4.4 %。以硅胶管为采样滤料,采样效率>95 %。样品室温下可保存7 d以上。 结论: 该方法采样效率高,操作简便,精密度和灵敏度较高,可以满足工作场所空气中对氨基苯甲醚的测定。.

Keywords: High performance liquid; P-Anisidine; Workplace; chromatography.

MeSH terms

  • Air Pollutants, Occupational / analysis*
  • Aniline Compounds / analysis*
  • Chromatography, High Pressure Liquid / methods*
  • Humans
  • Limit of Detection
  • Workplace*

Substances

  • Air Pollutants, Occupational
  • Aniline Compounds
  • 4-anisidine