Real-world comparison of the new 34 mm self-expandable transcatheter aortic prosthesis Evolut R to its 31 mm core valve predecessor

Catheter Cardiovasc Interv. 2019 Mar 1;93(4):685-691. doi: 10.1002/ccd.27862. Epub 2018 Oct 2.

Abstract

Objectives: The aim of the present study was to compare the incidence of periprocedural complications and short-term outcomes between the second-generation recapturable 34 mm Evolut-R and its first-generation 31 mm predecessor.

Background: Although already in extensive clinical use in real world patients, the periprocedural complications and clinical outcomes of the new 34 mm device have not been investigated yet.

Methods: Consecutive patients who had undergone transcatheter aortic valve implantation in two centers with either a 31 mm CoreValve or a 34 mm Evolut-R device were retrospectively studied. Periprocedural complications of malpositioning, valve-in-valve implantation, conversion to full sternotomy or percutaneous coronary intervention and vascular complications were compared between the two groups. Short-term outcomes at discharge were compared using Valve Academic Research Consortium (VARC-2) criteria.

Results: The study group included 106 patients (35 Evolut-R 34 mm; 71 CoreValve 31 mm). Significantly lower rates of valve-in-valve implantation were demonstrated for the 34 mm group compared to the first-generation device (0% vs. 11.9%, respectively, P = 0.036). All other periprocedural complications were similar between groups. At discharge, the rates of new pacemaker implantation (5.7% vs. 26.8%, P = 0.037) and bleeding complications (2.9% vs. 19.6%, P = 0.025) were statistically significantly lower among the 34 mm group. With regards to VARC-2 defined combined endpoints, rates of early safety were significantly improved among the 34 mm group compared to 31 mm group (0% vs. 27.9%, respectively, P = 0.004).

Conclusions: The recently introduced 34 mm Evolut-R seems to demonstrate an improved safety profile, as evidenced by the reduced bleeding rates, lower rates of valve-in-valve implantation and lower PPM rates compared to its 31 mm predecessor.

Keywords: TAVI; complications; pacemaker.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Female
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Postoperative Complications / etiology
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects
  • Transcatheter Aortic Valve Replacement / instrumentation*
  • Treatment Outcome