Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging

Eur Radiol. 2019 Jun;29(6):3159-3169. doi: 10.1007/s00330-018-5813-4. Epub 2018 Dec 5.

Abstract

Objectives: To determine the diagnostic accuracy and interobserver concordance of whole-body (WB)-MRI, vs. 99mTc bone scintigraphy (BS) and 18fluoro-ethyl-choline (18F-choline) PET/CT for the primary staging of intermediate/high-risk prostate cancer.

Methods: An institutional review board approved prospective cohort study carried out between July 2012 and November 2015, whereby 56 men prospectively underwent 3.0-T multiparametric (mp)-WB-MRI in addition to BS (all patients) ± 18F-choline PET/CT (33 patients). MRI comprised pre- and post-contrast modified Dixon (mDixon), T2-weighted (T2W) imaging, and diffusion-weighted imaging (DWI). Patients underwent follow-up mp-WB-MRI at 1 year to derive the reference standard. WB-MRIs were reviewed by two radiologists applying a 6-point scale and a locked sequential read (LSR) paradigm for the suspicion of nodal (N) and metastatic disease (M1a and M1b).

Results: The mean sensitivity/specificity of WB-MRI for N1 disease was 1.00/0.96 respectively, compared with 1.00/0.82 for 18F-choline PET/CT. The mean sensitivity and specificity of WB-MRI, 18F-choline PET/CT, and BS were 0.90/0.88, 0.80/0.92, and 0.60/1.00 for M1b disease. ROC-AUC did not show statistically significant improvement for each component of the LSR; mean ROC-AUC 0.92, 0.94, and 0.93 (p < 0.05) for mDixon + DWI, + T2WI, and + contrast respectively. WB-MRI had an interobserver concordance (κ) of 0.79, 0.68, and 0.58 for N1, M1a, and M1b diseases respectively.

Conclusions: WB-MRI provides high levels of diagnostic accuracy for both nodal and metastatic bone disease, with higher levels of sensitivity than BS for metastatic disease, and similar performance to 18F-choline PET/CT. T2 and post-contrast mDixon had no significant additive value above a protocol comprising mDixon and DWI alone.

Key points: • A whole-body MRI protocol comprising unenhanced mDixon and diffusion-weighted imaging provides high levels of diagnostic accuracy for the primary staging of intermediate- and high-risk prostate cancer. • The diagnostic accuracy of whole-body MRI is much higher than that of bone scintigraphy, as currently recommended for clinical use. • Staging using WB-MRI, rather than bone scintigraphy, could result in better patient stratification and treatment delivery than is currently provided to patients worldwide.

Keywords: Choline; Magnetic resonance imaging; Positron emission tomography; Prostate.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Bone Neoplasms / diagnosis
  • Bone Neoplasms / secondary*
  • Diffusion Magnetic Resonance Imaging / methods*
  • Humans
  • Lymph Nodes / diagnostic imaging*
  • Lymphatic Metastasis / diagnosis
  • Male
  • Middle Aged
  • Neoplasm Staging / methods*
  • Positron Emission Tomography Computed Tomography / methods
  • Prospective Studies
  • Prostatic Neoplasms / diagnosis*
  • Prostatic Neoplasms / secondary
  • ROC Curve
  • Reproducibility of Results
  • Whole Body Imaging / methods*