Progressive deconstruction with flow diversion using a Pipeline embolization device (PED; Medtronic) can be utilized to promote thrombosis of broad-based fusiform aneurysms. Current flow diverters require a 0.027-inch microcatheter for deployment. The authors present a patient with a fusiform P2-3 junction posterior cerebral artery aneurysm in which they demonstrate the importance of haptics in microwire manipulation to recognize large-vessel anatomy versus perforator anatomy that may overlap, especially when access is needed in distal tortuous circulations. In addition, the authors demonstrate the need for appropriate visualization before PED deployment. Postembolization runs demonstrated optimal wall apposition with contrast stasis within the aneurysm dome.The video can be found here: https://youtu.be/8kfsSvN3XqM.
Keywords: Pipeline embolization device; flow diversion; posterior cerebral artery; video.