False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up

J Vasc Surg. 2019 Sep;70(3):710-717. doi: 10.1016/j.jvs.2018.11.038. Epub 2019 Mar 6.

Abstract

Objective: Failure of thoracic endovascular aortic repair (TEVAR) in chronic aortic dissections can be partially explained by retrograde false lumen (FL) flow through distal re-entry tears. After implantation of a thoracic stent graft, FL thrombosis occurs in less than 50% of the cases. The objectives of this study were to describe the feasibility and outcomes of FL embolization in patients with chronic aortic dissections.

Methods: Between June 2015 and January 2018, 27 patients (mean age, 61 ± 14 years) with chronic aortic dissection underwent FL embolization as an adjunct during or after TEVAR placement procedure. Indications for embolization were (1) symptomatic chronic aortic dissections with pain or rapid growth of aortic diameter (≥5 mm/y) requiring rapid exclusion of the aneurysm, (2) aneurysmal dilatation with persistent FL retrograde flow after TEVAR, and (3) large FL aneurysms (≥55 mm) that might lead to persistent retrograde flow. Twenty patients presented with type B chronic aortic dissections (74.1%) and seven presented a residual type A chronic aortic dissections (25.9%). Eight patients had a previous aortic arch replacement (29.6%). Six patients had previous repair with TEVAR (22.2%). The delay between the onset of dissection and the first endovascular repair was 47 months (range, 3-144). Spinal fluid drainage was used in 74.1% of cases (20/27 patients). Embolization devices included coils and vascular plugs.

Results: The technical success rate was 100% (27/27). Complete spinal cord ischemia was observed in one patient (3.7%). There was one hospital death from pneumonia after zone 1 supra-aortic trunk debranching with TEVAR and embolization. After the index procedure, FL thrombosis was observed in 81.5% of patients (22/27) on late phase computed tomography angiography. Five patients required two or more embolization procedures, leading to a high rate of complete FL thrombosis (92.6%). One patient presented a type IB endoleak and one patient presented a type II endoleak. Radiologic follow-up was 20 ± 10 months. The maximum thoracic aortic diameter significantly decreased from 63 mm to 54 ± 10 mm (P < .001).

Conclusions: Embolization of the FL of chronic aortic dissections is technically feasible with a low morbidity rate. The FL thrombosis is observed in the majority of case and promotes favorable thoracic aortic remodeling. Longer follow-up is needed to confirm these good results on the thoracic aorta and this technique may, therefore, improve the results of TEVAR in chronic aortic dissections.

Keywords: Chronic aortic dissection; Embolization; False lumen thrombosis; TEVAR.

MeSH terms

  • Aged
  • Aorta, Thoracic / diagnostic imaging
  • Aorta, Thoracic / physiopathology
  • Aorta, Thoracic / surgery*
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / physiopathology
  • Aortic Aneurysm, Thoracic / therapy*
  • Aortic Dissection / diagnostic imaging
  • Aortic Dissection / physiopathology
  • Aortic Dissection / therapy*
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Databases, Factual
  • Embolization, Therapeutic* / adverse effects
  • Endoleak / etiology
  • Endovascular Procedures* / adverse effects
  • Feasibility Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Spinal Cord Ischemia / etiology
  • Time Factors
  • Treatment Outcome
  • Vascular Remodeling*