Iatrogenic aortic regurgitation after radiofrequency ablation of idiopathic ventricular arrhythmias originating from the aortic valvular region

Heart Rhythm. 2019 Aug;16(8):1189-1195. doi: 10.1016/j.hrthm.2019.03.010. Epub 2019 Mar 13.

Abstract

Background: Radiofrequency ablation at the aortic root has the potential risk of aortic regurgitation (AR).

Objective: This study investigated the incidence and clinical features of iatrogenic AR after catheter ablation of idiopathic ventricular arrhythmias originating from the aortic root.

Methods: We studied 45 consecutive patients with idiopathic ventricular arrhythmias originating from the aortic cusps (ACs; AC group; n = 32 [71%]) and papillary muscles (control group; n = 13 [29%]) who underwent ablation via a retrograde aortic approach and serial echocardiography before and within 24 hours after the ablation procedure. No patients had preexisting AR.

Results: After ablation, mild AR occurred in 5 AC group patients and 1 control group patient. Regurgitant flow was observed at the center of the aortic leaflets in 3 patients, the left coronary cusp-noncoronary cusp commissure in 2 patients, and both in 1 patient. No patients undergoing ablation only above the aortic valve developed AR. In AC group patients, the occurrence of AR was associated with a longer ablation time (24 ± 14 minutes vs 10 ± 5 minutes; P < .01) and higher average output (36.6 ± 4.2 W vs 32.0 ± 3.2 W; P = .01). The same severity of AR still existed after 16.2 ± 3.6 months of follow-up. No patients required any additional medical management or surgical intervention.

Conclusion: Iatrogenic mild AR after ablation in the aortic root occurred with a noticeable prevalence, which was associated with extensive ablation both above and below the ACs as well as catheter-related mechanical factors. Although it did not appear to aggravate the hemodynamic status during the mid-term follow-up, careful monitoring of AR progression should be considered.

Keywords: Aortic cusp; Aortic regurgitation; Complications; Idiopathic ventricular arrhythmia; Radiofrequency catheter ablation.

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology*
  • Aortic Valve Insufficiency / diagnosis
  • Aortic Valve Insufficiency / etiology*
  • Aortic Valve Insufficiency / physiopathology
  • Catheter Ablation / adverse effects*
  • Echocardiography, Doppler, Color
  • Electrophysiologic Techniques, Cardiac / methods*
  • Female
  • Follow-Up Studies
  • Humans
  • Iatrogenic Disease*
  • Male
  • Middle Aged
  • Tachycardia, Ventricular / physiopathology
  • Tachycardia, Ventricular / surgery*
  • Ventricular Function, Left / physiology*