Objective: To measure the actual radiation dose delivered by imaging techniques commonly used in the radiography of suspected physical abuse and to make this information available to health professionals and families.
Methods: Data were collected retrospectively on children under 3 years referred for skeletal surveys for suspected physical abuse, non-contrast CT head scan or radionuclide imaging of the bones in Starship Children's Hospital, Auckland, New Zealand from January to December 2015. Patient size-specific conversion coefficients were derived from International Commission on Radiologic Protection tissue weighting factors and used to calculate effective dose.
Results: Seventy-one patients underwent an initial skeletal survey, receiving a mean effective dose of 0.20 mSv (95% CI 0.18 to 0.22). Sixteen patients had a follow-up survey with a mean effective dose of 0.10 mSv (95% CI 0.08 to 0.11). Eighty patients underwent CT head which delivered a mean effective dose of 2.49 mSv (95% CI 2.37 to 2.60). Thirty-nine patients underwent radionuclide bone imaging which delivered a mean effective dose of 2.27 mSv (95% CI 2.11 to 2.43).
Conclusions: In a paediatric centre, skeletal surveys deliver a relatively low effective radiation dose, equivalent to approximately 1 month of background radiation. Non-contrast CT head scan and radionuclide bone imaging deliver similar doses, equivalent to approximately 1 year of background radiation. This information should be considered when gaining informed consent and incorporated in patient education handouts.
Keywords: patient education handout; physical abuse; radiography; radionuclide imaging.
© Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.