Detectability of the choroid plexus of the third ventricle with magnetic resonance ventriculography

Jpn J Radiol. 2019 Jun;37(6):449-457. doi: 10.1007/s11604-019-00834-2. Epub 2019 Apr 23.

Abstract

Purpose: To clarify the detectability of the choroid plexus of the third ventricle (ChPl3V) with magnetic resonance ventriculography (MRVn) employing a steady-state free precession (SSFP) sequence in comparison to surgical endoscopic movies as a golden standard, as we encountered some clinical cases of total agenesis of corpus callosum (ACC) where we could not recognize the choroid plexus of the third ventricle and found no previous article addressing this problem.

Materials and methods: This retrospective study included consecutive patients from 2010 to 2016 for whom endoscopic evaluation of the third ventricle was conducted. The anterior portion of the right and left streaks of ChPl3V was evaluated in 8 patients on 16 sites, while the posterior portion of both streaks of ChPl3V was evaluated in 13 patients on 26 sites. Sensitivity of MRVn to visualize ChPl3V with endoscopic movies as the golden standard was calculated.

Results: Sensitivity of MRVn in visualizing the anterior portion of ChPl3V was 0.813, and that for the posterior portion 0.692. The anterior portion of ChPl3V was visualized in all cases where no tumor contacted the foramen of Monro.

Conclusion: MRVn visualizes the anterior portion of ChPl3V with significant sensitivity and the posterior portion with lower one.

Keywords: Choroid plexus; Magnetic resonance imaging (MRI); The third ventricle.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Cerebral Ventriculography / methods*
  • Child
  • Choroid Plexus / diagnostic imaging*
  • Female
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Retrospective Studies
  • Sensitivity and Specificity
  • Third Ventricle / diagnostic imaging*
  • Young Adult