Modern cup alignment techniques in total hip arthroplasty: A systematic review

Orthop Traumatol Surg Res. 2019 Sep;105(5):907-913. doi: 10.1016/j.otsr.2019.03.015. Epub 2019 May 1.

Abstract

Introduction: A systematic review was conducted to assess the clinical and radiological outcomes of the alternative surgical techniques that consider the dynamic aspect of the acetabular orientation when aligning a cup (pelvic tilt-, lumbo-pelvic kinematics-, and spine-hip relationship-adjusted cup alignment techniques).

Method: Eight eligible articles reported the outcomes of total hip arthroplasty (THA) performed with alternative techniques. Clinical and radiological data were extracted. One study had a control group of patients who underwent conventional THAs (level III) while the seven other studies were level IV. Computer navigation system (CAS), Optimized Positioning System (OPS™), and manual instrumentation were used to align components in four, two, and two studies, respectively. A meta-analysis was not carried out because there was a lack of homogeneity between included articles regarding the method to position the cup and the nature of the reported data.

Results: THA performed with alternative techniques had an early dislocation rate ranging from 0 to 1.9%, no unexpected catastrophic failure, and acceptable radiographic cup orientations. One study compared kinematically and mechanically aligned THAs and found no dislocation in either groups, similar patient reported outcome measures (43 Oxford-12 Score for both groups), and similar proportions of cup in the Lewinnek zone (respectively 65% and 70%).

Discussion/conclusion: Alternative methods accounting for the functional acetabular orientation seem to be clinically safe and effective in the early-term, and generate acceptable cup orientation on radiographs. Their values compare to those of more conventional techniques for cup implantation remain to be determined. We developed a classification of the multiple methods for aligning an acetabular component.

Level of evidence: IV, systematic review of level III and IV studies.

Keywords: Cup alignment; Functional alignment; Kinematic alignment; Lumbar stiffness; Lumbo-pelvic kinematics; Spine-hip relation; Total hip replacement.

Publication types

  • Systematic Review

MeSH terms

  • Acetabulum / diagnostic imaging
  • Acetabulum / surgery*
  • Arthroplasty, Replacement, Hip / methods*
  • Hip Dislocation / prevention & control*
  • Hip Prosthesis*
  • Humans
  • Osteoarthritis, Hip / diagnosis
  • Osteoarthritis, Hip / surgery
  • Patient Reported Outcome Measures*
  • Prosthesis Design
  • Radiography