Is Ductography Still Warranted in the 21st century?

Breast J. 2019 Jul;25(4):654-662. doi: 10.1111/tbj.13302. Epub 2019 May 13.

Abstract

Objective: To determine the utility of ductography in conjunction with mammography and ultrasound in patients with pathologic nipple discharge, and the incremental role of MRI after triple-modality evaluation.

Materials and methods: We retrospectively reviewed the medical records of patients who had presented with pathologic nipple discharge and had undergone mammography and/or ultrasound and ductography between January 1, 2005, and October 31, 2010. We tested the diagnostic sensitivity, specificity and accuracy of combined triple-modality evaluation as well as of MRI performed in addition to these imaging techniques. We used the gold standard of image-guided biopsies, surgical excision, or long-term clinical and imaging follow-up.

Results: Among 94 study patients, benign papillomas were identified in 42 (44.7%), abscess in one (1%), duct ectasia in four (4.3%), and malignancy (invasive ductal carcinoma or ductal carcinoma in situ) or high-risk lesion (atypical ductal hyperplasia) in 10 (10.6%). Forty-six patients (49%) underwent surgical excision; 89.1% of which had presurgical planning with ductography. In 35 (37.2%) with negative imaging, resolution of nipple discharge was confirmed on median clinical and imaging follow-up of 36 months. Two patients with negative imaging were lost to follow-up. Sensitivity, specificity, PPV, and NPV for accurately demonstrating the etiology of pathologic nipple discharge were 13%, 97%, 89%, and 37% respectively for mammography; 73%, 97%, 98%, and 64% respectively for ultrasound; 76%, 72%, 84%, and 61% respectively for ductography; 86%, 70%, 85%, and 72% respectively for combined ultrasound and ductography; and 75%, 100%, 100% and 67% respectively for DCE-MRI.

Conclusion: The combination of mammography, ultrasound and ductography is highly accurate for identifying the etiology of pathologic nipple discharge. DCE-MRI can be used as an alternate to ductography if necessary.

Keywords: DCE-MRI; breast; ductography; pathologic nipple discharge; ultrasound.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Breast Diseases / diagnostic imaging
  • Breast Diseases / pathology*
  • Breast Neoplasms / diagnostic imaging
  • Breast Neoplasms / pathology
  • Contrast Media
  • Female
  • Humans
  • Image-Guided Biopsy
  • Magnetic Resonance Imaging / methods
  • Mammography / methods*
  • Mammography / statistics & numerical data
  • Middle Aged
  • Nipple Discharge / diagnostic imaging*
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography, Mammary
  • Young Adult

Substances

  • Contrast Media