Background: The treatment of persistent air leak is a challenge. Herein, we reported the combined intrabronchial and intrapleural injection of fibrin glue using fiber bronchoscopy to seal off an alveolar pleura fistula developed following necrotizing pneumonia in high-risk patient.
Case presentation: A 74-year-old man was intubated in emergency for acute ischemic stroke. Percutaneous dilatational tracheostomy was then performed, and 15 days later patient returned to spontaneous breathing. However, he developed alveolar pleural fistula following necrotizing pneumonia with persistent air leaks. The intrabronchial and intrapleural injection of fibrin glue using fiber bronchoscopy sealed off the alveolar pleura fistula after that other endoscopic treatments as bronchial valve and intrabronchial fibrin glue application had failed.
Conclusions: Our strategy is safe and easy to reproduce. It represents an additional method in the armamentarium of the physicians for the management of PAL when all standard strategies are unfeasible or fail.
Keywords: Alveolar pleural fistula; Case report; Fibrin glue; Persistent air leaks.