Background: Radiofrequency high-power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI).
Objectives: This study aimed to report the procedural data and initial results of a combined ablation technique using AI-guided high-power (AI-HP; 50 W) ablation for PVI.
Methods: Symptomatic AF patients were consecutively enrolled and underwent wide-area contiguous circumferential PVI. Contact-force catheters were used, ablation power was set to 50 W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy.
Results: PVI was achieved in all (n = 50, mean age: 68 ± 9 years, female: 60%) patients, rate of first-round PVI was 92%. A total of N = 2105 AI-guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5 ± 8 vs 8.6 ± 3 and 12.2 ± 4 vs 9.3 ± 3; mean contact force (g): 17.1 ± 12 vs 25.4 ± 14 and 33.7 ± 13 vs 21.0 ± 11; mean AI: 547 ± 48 vs 445 ± 55 and 555 ± 56 vs 440 ± 47 (all P < .0001). Procedure and fluoroscopy time (minute) were 55.6 ± 6.6 and 6 ± 1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In-hospital and 1-month follow-up no major complications such as death, stroke, tamponade, or atriaesophageal fistula (AE) occurred. Preliminary 6-month follow-up showed 48 of 50 (96%) patients were free from clinical AF/atrial tachycardia recurrence.
Conclusion: AI-HP (50 W) ablation appears to be a feasible, safe, fast, and effective ablation technique for PVI.
Keywords: ablation; ablation index; atrial fibrillation; high power; pulmonary vein isolation.
© 2019 Wiley Periodicals, Inc.