Paraspinous Muscle Flaps for the Treatment of Complex Spinal Wounds

Spine (Phila Pa 1976). 2020 May 1;45(9):599-604. doi: 10.1097/BRS.0000000000003341.

Abstract

MINI: This retrospective case series investigated paraspinous flaps for coverage of complex spinal wounds. 6.90% of patients developed postoperative wound infections and 0.00% of patients required instrumentation removal for infection. This suggests that these flaps may offer a long-term solution in wound management for patients with repeated spinal operations.

Study design: Retrospective case series.

Objective: To investigate the efficacy and complication profile of the use of paraspinous muscle flaps for closure of complex spinal wounds.

Summary of background data: Paraspinous muscle flap closure offers an innovative option in difficult-to-manage post-spinal surgery wounds. Current literature reports are mixed in terms of success and complication rates of these flap procedures, with most sources citing a wound complication rate of 20%.

Methods: This case series investigated the hospital course of 58 patients undergoing paraspinous flap closure after spinal surgery between the years 2014 and 2018. Information gathered includes: demographics, surgery indication, location, and length of incision on the spine, nutrition labs, previous spinal surgeries, preoperative wound class, operative times, length of hospital stay, and complication rates including reoperation, wound infection, and other postoperative complications.

Results: Of the 58 patients undergoing spinal muscle flap closure, 51 (87.93%) had undergone previous spinal surgery with an average of 2.12 previous surgeries in these patients. Mean albumin and prealbumin were 2.62 and 13.75, respectively. 4/58 (6.90%) developed a wound infection or experienced a continuation of their chronic osteomyelitis. Of the 57 patients that had spinal instrumentation, three (5.26%) had spinal implants removed at the time of surgery and two (3.51%) had it removed or replaced later for mechanical complications. No patients had instrumentation removed for chronic infections. One (1.72%) experienced reoperation for wound-related complications. These rates are lower than most complication rates in the current literature.

Conclusion: The plastic and reconstructive paraspinous muscle flap has promising results as a closure option for complex spinal wounds following neurosurgical cases. Further investigation is called for to determine the applicability of these results to the general population.

Level of evidence: 4.

Plain language summary

Retrospective case series. To investigate the efficacy and complication profile of the use of paraspinous muscle flaps for closure of complex spinal wounds. Paraspinous muscle flap closure offers an innovative option in difficult-to-manage post-spinal surgery wounds. Current literature reports are mixed in terms of success and complication rates of these flap procedures, with most sources citing a wound complication rate of 20%. This case series investigated the hospital course of 58 patients undergoing paraspinous flap closure after spinal surgery between the years 2014 and 2018. Information gathered includes: demographics, surgery indication, location, and length of incision on the spine, nutrition labs, previous spinal surgeries, preoperative wound class, operative times, length of hospital stay, and complication rates including reoperation, wound infection, and other postoperative complications. Of the 58 patients undergoing spinal muscle flap closure, 51 (87.93%) had undergone previous spinal surgery with an average of 2.12 previous surgeries in these patients. Mean albumin and prealbumin were 2.62 and 13.75, respectively. 4/58 (6.90%) developed a wound infection or experienced a continuation of their chronic osteomyelitis. Of the 57 patients that had spinal instrumentation, three (5.26%) had spinal implants removed at the time of surgery and two (3.51%) had it removed or replaced later for mechanical complications. No patients had instrumentation removed for chronic infections. One (1.72%) experienced reoperation for wound-related complications. These rates are lower than most complication rates in the current literature. The plastic and reconstructive paraspinous muscle flap has promising results as a closure option for complex spinal wounds following neurosurgical cases. Further investigation is called for to determine the applicability of these results to the general population. Level of Evidence: 4.

MeSH terms

  • Adult
  • Aged
  • Cohort Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Neurosurgical Procedures / adverse effects
  • Paraspinal Muscles / transplantation*
  • Plastic Surgery Procedures / methods*
  • Reoperation / adverse effects
  • Retrospective Studies
  • Spinal Diseases / diagnosis
  • Spinal Diseases / etiology
  • Spinal Diseases / surgery*
  • Surgical Flaps / transplantation*
  • Surgical Wound / diagnosis
  • Surgical Wound / etiology
  • Surgical Wound / surgery*
  • Surgical Wound Infection / diagnosis
  • Surgical Wound Infection / etiology
  • Surgical Wound Infection / surgery
  • Treatment Outcome