Added value of 18F-FDG-PET/CT and cardiac CTA in suspected transcatheter aortic valve endocarditis

J Nucl Cardiol. 2021 Oct;28(5):2072-2082. doi: 10.1007/s12350-019-01963-x. Epub 2019 Dec 2.

Abstract

Backgrounds: Transcatheter-implanted aortic valve infective endocarditis (TAVI-IE) is difficult to diagnose when relying on the Duke Criteria. Our aim was to assess the additional diagnostic value of 18F-fluorodeoxyglucose (18F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) in suspected TAVI-IE.

Methods: A multicenter retrospective analysis was performed in all patients who underwent 18F-FDG-PET/CT and/or CTA with suspected TAVI-IE. Patients were first classified with Duke Criteria and after adding 18F-FDG-PET/CT and CTA, they were classified with European Society of Cardiology (ESC) criteria. The final diagnosis was determined by our Endocarditis Team based on ESC guideline recommendations.

Results: Thirty patients with suspected TAVI-IE were included. 18F-FDG-PET/CT was performed in all patients and Cardiac CTA in 14/30. Using the Modified Duke Criteria, patients were classified as 3% rejected (1/30), 73% possible (22/30), and 23% definite (7/30) TAVI-IE. Adding 18F-FDG-PET/CT and CTA supported the reclassification of 10 of the 22 possible cases as "definite TAVI-IE" (5/22) or "rejected TAVI-IE" (5/22). This changed the final diagnosis to 20% rejected (6/30), 40% possible (12/30), and 40% definite (12/30) TAVI-IE.

Conclusions: Addition of 18F-FDG-PET/CT and/or CTA changed the final diagnosis in 33% of patients and proved to be a valuable diagnostic tool in patients with suspected TAVI-IE.

Keywords: CT; Infection; PET; valvular heart disease.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Endocarditis / diagnostic imaging*
  • Endocarditis / surgery
  • Female
  • Fluorodeoxyglucose F18 / therapeutic use*
  • Humans
  • Male
  • Positron Emission Tomography Computed Tomography / methods
  • Positron Emission Tomography Computed Tomography / standards*
  • Positron Emission Tomography Computed Tomography / trends
  • Retrospective Studies
  • Statistics, Nonparametric
  • Tomography, X-Ray Computed / methods
  • Tomography, X-Ray Computed / standards*
  • Tomography, X-Ray Computed / trends
  • Transcatheter Aortic Valve Replacement / instrumentation
  • Transcatheter Aortic Valve Replacement / methods
  • Transcatheter Aortic Valve Replacement / statistics & numerical data

Substances

  • Fluorodeoxyglucose F18