Background: Radiofrequency catheter ablation of idiopathic ventricular arrhythmias (VAs) is performed to eliminate symptoms and to prevent or reverse arrhythmia-induced cardiomyopathy. Preprocedural prediction of the chamber of VA origin is critical for patient counseling, procedure planning, and guidance of invasive mapping.
Objective: We aimed to assess the performance of manual expert versus automated 12-lead electrocardiogram (ECG) analysis in the prediction of VA origin.
Methods: Patients with ablation of idiopathic VA and sustained success were included. The VA origin was defined as the site where ablation caused arrhythmia suppression. Standard baseline 12-lead ECGs with documentation of the VA were analyzed manually in a blinded fashion by three electrophysiologists and three electrophysiology (EP) fellows. In addition, the same standard 12-lead ECG was analyzed by an automated computer algorithm using a vectorcardiographic approach.
Results: Thirty-eight patients (median age, 47 [interquartile range, 37-58]; 68% female) were enrolled. The VA originated from the right ventricle in 24 (63%) and the left ventricle in 14 (37%) patients. The electrophysiologists and EP fellows identified the VA chamber of origin with a similar accuracy of 73% and 72% (P = .72). The automated algorithm showed a higher accuracy of 89% (P = .03 compared with electrophysiologists and EP fellows). This resulted in a sensitivity of 95% and specificity of 86%.
Conclusion: While the manual ECG analysis of the standard 12-lead ECG by both electrophysiologists and EP fellows correctly identified the chamber of VA origin in around 75% of cases, an automated vectorcardiographic computer algorithm achieved an accuracy of 89% with clinically acceptable diagnostic parameters.
Keywords: ECG; catheter ablation; computational prediction; idiopathic ventricular arrhythmia; premature ventricular complex.
© 2019 Wiley Periodicals, Inc.