Recurrence After Curative Resection of Hepatitis B Virus-Related Hepatocellular Carcinoma: Diagnostic Algorithms on Gadoxetic Acid-Enhanced Magnetic Resonance Imaging

Liver Transpl. 2020 Jun;26(6):751-763. doi: 10.1002/lt.25713. Epub 2020 Apr 21.

Abstract

Small recurrent hepatocellular carcinoma (HCC) can show atypical imaging patterns, and a specific diagnostic algorithm for HCC is lacking. This study aimed to better characterize postoperative recurrent HCCs <20 mm in size with gadoxetic acid-enhanced magnetic resonance imaging (MRI). We evaluated 373 newly developed nodules after hepatectomy in 204 HCC patients with chronic hepatitis B virus infection. The diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS) version 2018 was calculated with gadoxetic acid-enhanced MRI to characterize recurrent HCC. Modified diagnostic algorithms were proposed by combining significant imaging biomarkers related to subcentimeter and 10-19 mm recurrence, and the algorithms were then compared with the LI-RADS system. A total of 256 recurrent HCCs (108 recurrent HCCs <10 mm in size; 148 recurrent HCCs 10-19 mm in size) were confirmed via histology or follow-up imaging. Nonrim arterial phase hyperenhancement (APHE) and 3 LI-RADS ancillary features (AFs; hepatobiliary phase hypointensity, mild-moderate T2 hyperintensity, and restricted diffusion) were significantly related to recurrent HCCs <20 mm in size according to a multivariate analysis. For subcentimeter recurrence, combining at least 2 of the 3 AFs only achieved better specificity (sensitivity, 83.3%; specificity, 87.7%) than the LR-4 category (sensitivity, 88.9%, P = 0.21; specificity, 70.8%, P = 0.006). For 10-19 mm recurrences, combining nonrim APHE and at least 1 of the 3 AFs achieved only a significantly enhanced sensitivity of 85.1% but a lower specificity of 86.5% compared with the LR-5 category (sensitivity: 63.5%, P < 0.001; specificity: 94.2%, P = 0.13). In conclusion, the diagnostic algorithms for subcentimeter and 10-19 mm recurrent HCCs should be stratified. Combining at least 2 AFs demonstrated comparable sensitivity with significantly enhanced specificity compared with the LR-4 category for characterizing subcentimeter recurrence.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Carcinoma, Hepatocellular* / diagnostic imaging
  • Carcinoma, Hepatocellular* / surgery
  • Contrast Media
  • Gadolinium DTPA
  • Hepatitis B virus
  • Hepatitis B, Chronic* / complications
  • Hepatitis B, Chronic* / diagnostic imaging
  • Humans
  • Liver Neoplasms* / diagnostic imaging
  • Liver Neoplasms* / surgery
  • Liver Transplantation*
  • Magnetic Resonance Imaging
  • Neoplasm Recurrence, Local / diagnostic imaging
  • Retrospective Studies
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • gadolinium ethoxybenzyl DTPA
  • Gadolinium DTPA