Development of a total serum testosterone, androstenedione, 17-hydroxyprogesterone, 11β-hydroxyandrostenedione and 11-ketotestosterone LC-MS/MS assay and its application to evaluate pre-analytical sample stability

Clin Chem Lab Med. 2020 Apr 28;58(5):741-752. doi: 10.1515/cclm-2019-0959.

Abstract

Background Classically, serum testosterone (T) and androstenedione (A4) have been the mainstay for the biochemical assessment of hyperandrogenism. However, recent evidence suggests 11β-hydroxyandrostenedione (11OHA4) and 11-ketotestosterone (11KT) may also be important. Here, we describe the development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitation of total serum T, A4, 17-hydroxyprogesterone (17OHP), 11OHA4 and 11KT. In addition, we applied the method to assess pre-analytical stability. Methods An isotopically labelled internal standard was added to samples prior to supported liquid extraction (SLE). Extracts were analysed using LC-MS/MS to detect T/A4/17OHP/11OHA4 and 11KT along with their corresponding internal standards. Samples (n = 7) were collected from healthy volunteers (n = 14) and left incubated at 20 °C for up to 72 h. Tubes were retrieved at select time points, centrifuged, separated and frozen prior to analysis. Results The total run time was 4 min. For all analytes, intra- and inter-assay imprecision did not exceed 7.9% and 5.3%, respectively; matrix effects were negligible and mean recoveries ranged from 95.3 to 111.6%. The limits of quantitation (LOQs) were 0.25 nmol/L for T, A4 and 11OHA4, 0.50 nmol/L for 17OHP, and 0.24 nmol/L for 11KT. No significant change was observed in pre-centrifugation A4 or female T concentrations over 72 h. Significant increases (p < 0.01) in concentrations of 11KT, 17OHP, 11OHA4 and male T were observed after 2, 8, 12 and 24 h, respectively. Conclusions We developed a robust LC-MS/MS assay for the quantitation of total serum T/A4/17OHP/11OHA4 and 11KT. Applying the method to determine pre-analytical stability suggests samples requiring 11KT need separating from the cells within 2 h.

Keywords: 11-ketotestosterone; 11β-hydroxyandrostenedione; androgens; mass spectrometry; stability.

MeSH terms

  • 17-alpha-Hydroxyprogesterone / blood*
  • 17-alpha-Hydroxyprogesterone / isolation & purification
  • 17-alpha-Hydroxyprogesterone / standards
  • Adult
  • Androstenedione / analogs & derivatives*
  • Androstenedione / blood*
  • Androstenedione / isolation & purification
  • Androstenedione / standards
  • Chromatography, High Pressure Liquid / methods*
  • Chromatography, High Pressure Liquid / standards
  • Female
  • Humans
  • Isotope Labeling
  • Limit of Detection
  • Liquid-Liquid Extraction
  • Male
  • Pre-Analytical Phase
  • Reference Standards
  • Reproducibility of Results
  • Tandem Mass Spectrometry / methods*
  • Tandem Mass Spectrometry / standards
  • Testosterone / analogs & derivatives*
  • Testosterone / blood*
  • Testosterone / isolation & purification
  • Testosterone / standards

Substances

  • Testosterone
  • Androstenedione
  • 11-hydroxyandrostenedione
  • 17-alpha-Hydroxyprogesterone
  • 11-ketotestosterone