Immediate and 1-year success rate of type 2 endoleak treatment using three-dimensional image fusion guidance

Diagn Interv Imaging. 2020 Sep;101(9):589-598. doi: 10.1016/j.diii.2020.02.001. Epub 2020 Feb 24.

Abstract

Purpose: To retrospectively assess immediate and 1-year success rate of type 2 endoleak (T2E) treatment with ethylene-vinyl-alcohol-polymer using three-dimensional (3D) image fusion guidance with cone beam computed tomography via trans-arterial embolization (TAE) or direct percutaneous sac injection (DPSI).

Materials and methods: A total of 37 patients with T2E who were treated either using TAE (34/37; 92%) or DPSI (9/37; 8%) were included. There were 34 men and 3 women with a mean age of 86±9 (SD) years (range: 67-104years). Mean aneurysm diameter was 67±14 (SD) mm (range: 42-101mm) at pre-procedure evaluation. Immediate success was complete embolization of the sac and feeding artery. 1-year success was reduction or stability of the aneurysmal sac diameter based on pre-procedure and 12-month follow-up examinations. Safety (treatment-related complications), patient demographics, duration of procedure and contrast volume were reported.

Results: Immediate and 1-year successful outcomes were reported in 94% (n=32) and 88% (n=28) of patients after TAE and 100% (n=9) and 89% (n=8) after DPSI. T2E treatments were immediately successful for 95% of the procedures (41/43) and for 88% (36/41) at 1year. Overall, T2E treatment was effective in 33 patients (89%). No major complications occurred. Mean procedure time and contrast volume were significantly different between the 2 techniques with respectively 87±16 (SD) min (range: 65-120min) and 75±26 (SD) mL (range: 40-130mL) for TAE and 32±10 (SD) min (range: 20-50min) (P<0.01) and 6±6 (SD) mL (range: 2-22mL) (P<0.01) for DPSI. Mean aneurysm diameter at 1-year was 68±17 (SD) mm (range: 43-101mm). No significant differences in the pre-procedure sac diameter were found at long-term follow-up between patients without T2E and those with persistent T2E (P=0.1) in the successful embolization group (n=33).

Conclusion: TAE or DPSI treatments of T2E with ethylene-vinyl-alcohol-polymer using 3D-image fusion guidance were immediately successful for 95% of the procedures and remained effective for 88%. Longer follow-up is necessary to assess sac stability in the case of persistent endoleak.

Keywords: Cone beam CT; Embolization; Endoleak; Endovascular aneurysm repair (EVAR); Ethylene-vinyl alcohol-polymer.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal* / diagnostic imaging
  • Aortic Aneurysm, Abdominal* / surgery
  • Blood Vessel Prosthesis Implantation*
  • Embolization, Therapeutic*
  • Endoleak / diagnostic imaging
  • Endoleak / therapy
  • Endovascular Procedures*
  • Female
  • Humans
  • Imaging, Three-Dimensional
  • Male
  • Retrospective Studies
  • Treatment Outcome