Simple 2-dimensional anatomic model to predict the risk of coronary obstruction during transcatheter aortic valve replacement

J Thorac Cardiovasc Surg. 2021 Oct;162(4):1075-1083.e1. doi: 10.1016/j.jtcvs.2020.01.085. Epub 2020 Feb 19.

Abstract

Objective: In this study, a 2-dimensional (2D) index relying on preprocedural computed tomography (CT) data was developed to evaluate the risk of coronary obstruction during transcatheter aortic valve replacement (TAVR) procedures.

Methods: Anatomic measurements from pre-TAVR CT scans were collected in 28 patients among 600 who were flagged as high risk (defined as meeting coronary artery height, h, <14 mm and/or sinus of Valsalva diameter, SOVd, <30 mm) for coronary obstruction. A geometric model derived from these anatomic measurements was used to predict the post-TAVR native cusp apposition relative to the coronary ostium. The distance from the cusp to the coronary ostium, DLC2D, was measured from the geometric model and indexed with the coronary artery diameter, d, to yield a fractional obstruction measure, DLC2D/d.

Results: Twenty-three of 28 high-risk patients successfully underwent TAVR without coronary obstruction, of whom 1 had coronary obstruction and 4 were deemed non-TAVR candidates. DLC2D/d differed significantly between the 2 groups (P < .0018), but neither h nor SOVd did (P > .32). The optimal sensitivity and specificity for DLC2D/d were 85% and occurred at a cutoff of 0.45. The optimal sensitivity and specificity of h and SOVd in this high-risk group were only 60% and 40%, respectively, for cutoffs of h = 10 mm and SOVd = 30.5 mm.

Conclusions: The 2D geometric model derived in this study shows promise for identifying patients with low-lying coronary ostium and/or small SOVd that may be safely treated with TAVR. DLC2D/d is more predictive of obstruction or poor TAVR candidacy compared with h and SOVd.

Keywords: FEA; TAVR; calcification; coronary obstruction; patient-specific.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aortic Valve Stenosis / surgery*
  • Computed Tomography Angiography / methods
  • Coronary Occlusion / diagnostic imaging*
  • Coronary Vessels* / diagnostic imaging
  • Coronary Vessels* / pathology
  • Coronary Vessels* / surgery
  • Female
  • Humans
  • Intraoperative Complications / etiology
  • Intraoperative Complications / prevention & control*
  • Male
  • Models, Anatomic
  • Patient-Specific Modeling
  • Preoperative Care / methods*
  • Risk Adjustment / methods
  • Tomography, X-Ray Computed / methods
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / methods
  • Treatment Outcome