A patient-independent CT intensity matching method using conditional generative adversarial networks (cGAN) for single x-ray projection-based tumor localization

Phys Med Biol. 2020 Jul 20;65(14):145009. doi: 10.1088/1361-6560/ab8bf2.

Abstract

A convolutional neural network (CNN)-based tumor localization method with a single x-ray projection was previously developed by us. One finding is that the discrepancy in the discrepancy in the intensity between a digitally reconstructed radiograph (DRR) of a three-dimensional computed tomography (3D-CT) and the measured x-ray projection has an impact on the performance. To address this issue, a patient-dependent intensity matching process for 3D-CT was performed using 3D-cone-beam computed tomography (3D-CBCT) from the same patient, which was sometimes inefficient and could adversely affect the clinical implementation of the framework. To circumvent this, in this work, we propose and validate a patient-independent intensity matching method based on a conditional generative adversarial network (cGAN). A 3D cGAN was trained to approximate the mapping from 3D-CT to 3D-CBCT from previous patient data. By applying the trained network to a new patient, a synthetic 3D-CBCT could be generated without the need to perform an actual CBCT scan on that patient. The DRR of the synthetic 3D-CBCT was subsequently utilized in our CNN-based tumor localization scheme. The method was tested using data from 12 patients with the same imaging parameters. The resulting 3D-CBCT and DRR were compared with real ones to demonstrate the efficacy of the proposed method. The tumor localization errors were also analyzed. The difference between the synthetic and real 3D-CBCT had a median value of no more than 10 HU for all patients. The relative error between the DRR and the measured x-ray projection was less than 4.8% ± 2.0% for all patients. For the three patients with a visible tumor in the x-ray projections, the average tumor localization errors were below 1.7 and 0.9 mm in the superior-inferior and lateral directions, resepectively. A patient-independent CT intensity matching method was developed, based on which accurate tumor localization was achieved. It does not require an actual CBCT scan to be performed before treatment for each patient, therefore making it more efficient in the clinical workflow.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms*
  • Cone-Beam Computed Tomography*
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Neoplasms / diagnostic imaging*
  • Phantoms, Imaging