Diagnostic Accuracy of PET/CT and Contrast Enhanced CT in Patients With Suspected Infected Aortic Aneurysms

Eur J Vasc Endovasc Surg. 2020 Jun;59(6):972-981. doi: 10.1016/j.ejvs.2020.01.032. Epub 2020 Apr 25.

Abstract

Objective: Infected aortic aneurysms are highly lethal, and management is very demanding, requiring an early diagnosis. The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT) and contrast enhanced CT (CE-CT) in patients with suspected infected aortic aneurysms.

Methods: PET/CT was performed in patients with clinically suspected infected aortic aneurysms, and additional CE-CT was performed if feasible. Diagnostic accuracy was assessed by two independent readers using a four point grading score for both imaging modalities. Maximum standardised uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity in PET/CT. The reference standard was a combination of clinical presentation, laboratory findings, and imaging.

Results: Ten patients were included prospectively in the study, 24 retrospectively; 16 patients (47%) prior to the start of antimicrobial treatment and all 34 patients prior to any vascular intervention. Thirteen of the 34 patients had an infected aortic aneurysm (38%). Proven infected aortic aneurysms were all metabolically active on PET/CT with a median SUVmax of 6.6 (interquartile range 4.7-21.8). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT for the diagnosis of infected aortic aneurysm was 100%, 71%, 68%, 100%, and 82%, for reader 1 and 85%, 71%, 65%, 88%, and 77%, for reader 2. Respective values for CE-CT, performed in 20 patients (59%), were 63%, 75%, 63%, 75%, and 70%, for reader 1 and 88%, 50%, 54%, 86%, and 65%, for reader 2.

Conclusion: The diagnostic accuracy of PET/CT in the detection of infected aortic aneurysms (n = 13) is high, and higher than CE-CT. While PET/CT demonstrates an excellent sensitivity, its specificity is hampered because of false positive findings.

Keywords: 18F-FDG; Computed tomography angiography; Data accuracy; Infected aneurysm; Infection; PET-CT.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aneurysm, Infected / diagnostic imaging*
  • Aorta
  • Aortic Aneurysm / diagnosis*
  • Contrast Media / administration & dosage*
  • False Positive Reactions
  • Female
  • Fluorodeoxyglucose F18 / administration & dosage
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Positron Emission Tomography Computed Tomography / methods*
  • Positron Emission Tomography Computed Tomography / standards
  • Predictive Value of Tests
  • Prospective Studies
  • Radiopharmaceuticals / administration & dosage*
  • Reference Standards
  • Retrospective Studies
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18