Impact of different conditions of breath-holding on the results of renal artery Doppler sonography: A pilot study

J Clin Ultrasound. 2020 Jul;48(6):315-323. doi: 10.1002/jcu.22843. Epub 2020 May 3.

Abstract

Purpose: To investigate the impact of different breath-holding conditions on the results of renal artery Doppler ultrasonography (RADS).

Methods: In 45 healthy volunteers, we performed RADS examination during breath-holding while breathing naturally and after a deep inspiration. We measured and compared peak systolic flow velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) of the right (RRA) and left (LRA) renal artery, and PSV, EDV, RI, acceleration time and acceleration index (AI) of the right and left interlobar arteries.

Results: The RRA and LRA PSV were, respectively, 76 ± 13 cm/s and 77 ± 15 cm/s under natural breathing and 93 ± 18 cm/s and 89 ± 24 cm/s after deep inspiration (P ≤ .001). The RRA and LRA EDV were also greater at deep inspiration (P < .001 and P = .019, respectively). There was no significant difference in RRA or LRA RI. The PSV, RI, and AI of the right and left interlobar arteries were greater after deep inspiration (P ≤ .001), without difference in AI.

Conclusion: Breath-holding conditions may influence Doppler measurements of renal artery flow velocity and should be reported and taken into account.

Keywords: Doppler ultrasonography; breath-holding; renal artery.

MeSH terms

  • Adult
  • Blood Flow Velocity
  • Breath Holding
  • Female
  • Humans
  • Male
  • Pilot Projects
  • Renal Artery / diagnostic imaging*
  • Ultrasonography, Doppler / methods*
  • Young Adult