Quantitative analysis of serum methohexital by GLC using capillary column and nitrogen-selective detection

Fundam Clin Pharmacol. 1988;2(6):551-8. doi: 10.1111/j.1472-8206.1988.tb00655.x.

Abstract

A gas chromatographic method for routine quantitation of methohexital in plasma samples is reported. One-step extraction in organic phase, the use of a fused silica capillary column, and nitrogen-selective detection permit simple, precise, and sensitive determination of methohexital in plasma. A linear relationship is described between peak height ratio and methohexital concentrations ranging from 0.125 to 50.0 micrograms/ml (r = 0.998). The sensitivity limit of the assay was 6 ng/ml in plasma. No interfering peak was observed with numerous other drugs. The procedure was successfully applied to the determination of pharmacokinetic parameters of methohexital after IV administration or continuous infusion in a child and an adult.

MeSH terms

  • Chemical Phenomena
  • Chemistry
  • Chromatography, Gas
  • Humans
  • Methohexital / blood*
  • Methohexital / metabolism
  • Methohexital / pharmacokinetics

Substances

  • Methohexital