Simulated clinical adjustment and intra-oral polishing of two translucent, monolithic zirconia dental ceramics: An in vitro investigation of surface roughness

J Dent. 2020 Oct:101:103447. doi: 10.1016/j.jdent.2020.103447. Epub 2020 Aug 5.

Abstract

Objective: To assess the surface roughness and residual flaws in two translucent zirconia substrates following simulated clinical adjustment and intra-oral finishing/polishing.

Materials and methods: Specimens were prepared from two translucent (5Y-ZP/8Y-ZP) and one conventional (3Y-TZP) zirconia substrates (n = 84 p/g). Arithmetic mean roughness parameter (Ra) was determined for all experimental groups at four stages (n = 21 p/g): (1) as-sintered, (2) surface grinding using a zirconia cutting diamond bur, (3) polishing using 1-step, 2-step or 4-step intra-oral polishing kits, and (4) laboratory polishing/glazing. Scanning electron microscopy (SEM) was used to evaluate residual surface flaws. Data were statistically analysed using a two-way ANOVA test, multiple and pairwise comparisons were performed using a Bonferroni post hoc test.

Results: Ra was significantly higher for as-sintered and ground 5Y-ZP/8Y-ZP compared to 3Y-TZP (p ≤ 0.001). Material type and polishing protocol had statistically significant effect on Ra (p < 0.001). The 4-step polishing resulted in the lowest Ra in 3Y-TZP/5Y-ZP (p ≤ 0.001). No significant differences were observed between different polishing protocols in 8Y-ZP (p≥0.655). Glazing significantly reduced Ra in all materials compared to other polishing protocols (p ≤ 0.001) except for the 4-step protocol in 3Y-TZP (p = 0.195). SEM revealed pronounced surface flaws in ground 5Y-ZP/8Y-ZP. Grinding of 3Y-TZP induced ductile material removal and thereby, minimal cohesive material loss. The 4-step polishing protocol resulted in the fewest and shallowest surface flaws in all groups. Glazing of 3Y-TZP resulted in the most homogenous surface contrary to 5Y-ZP/8Y-ZP.

Conclusions: The finest surface finish was achieved using the 4-step polishing protocol in all studied materials. This protocol might be inadequate however for polishing of ground 5Y-ZP/8Y-ZP as a result of the pronounced surface damage induced by the grinding process. The glazing of 5Y-ZP/8Y-ZP might not be as predictable as for 3Y-TZP.

Clinical significance: The higher susceptibility to surface damage, as a result of increasing dopant concentration, may render polishing of ground, translucent zirconia more complicated compared to the conventional 3Y-TZP counterparts.

Keywords: Cubic phase; Dental ceramics; Polishing; Surface roughness; Tetragonal phase; Translucent; Zirconia.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Ceramics
  • Dental Materials
  • Dental Polishing*
  • Materials Testing
  • Microscopy, Electron, Scanning
  • Surface Properties
  • Yttrium*
  • Zirconium

Substances

  • Dental Materials
  • Yttrium
  • Zirconium
  • zirconium oxide