Diagnostic performance of a whole-body dynamic 68GA-DOTATOC PET/CT acquisition to differentiate physiological uptake of pancreatic uncinate process from pancreatic neuroendocrine tumor

Medicine (Baltimore). 2020 Aug 14;99(33):e20021. doi: 10.1097/MD.0000000000020021.

Abstract

To evaluate the diagnostic performance of net influx rate (Ki) values from a whole-body dynamic (WBD) Ga-DOTATOC-PET/CT acquisition to differentiate pancreatic neuroendocrine tumors (pNETs) from physiological uptake of pancreatic uncinate process (UP).Patients who were benefited from a WBD acquisition for the assessment of a known well-differentiated neuroendocrine tumor (NET)/suspicion of disease in the prospective GAPET-NET cohort were screened. Only patients with a confirmed pNET/UP as our gold standard were included. The positron emission tomography (PET) procedure consisted in a single-bed dynamic acquisition centered on the heart, followed by a whole-body dynamic acquisition and then a static acquisition. Dynamic (Ki calculated according to Patlak method), static (SUVmax, SUVmean, SUVpeak) parameters, and tumor-to-liver and tumor-to-spleen ratio (TLRKi and TSRKi (according to hepatic/splenic Ki)), tumor SUVmax to liver SUVmax (TM/LM), tumor SUVmax to liver SUVmean (TM/Lm), tumor SUVmax to spleen SUVmax (TM/SM), and tumor SUVmax to spleen SUVmean (TM/Sm) (according to hepatic/splenic SUVmax and SUVmean respectively) were calculated. A Receiver Operating Characteristic (ROC) analysis was performed to evaluate their diagnostic performance to distinguish UP from pNET.One hundred five patients benefited from a WBD between July 2018 and July 2019. Eighteen (17.1%) had an UP and 26 (24.8%) a pNET. For parameters alone, the Ki and SUVpeak had the best sensitivity (88.5%) while the Ki, SUVmax, and SUVmean had the best specificity (94.4%). The best diagnostic accuracy was obtained with Ki (90.9%). For ratios, the TLRKi and the TSRKi had the best sensitivity (95.7%) while the TM/SM and TM/Sm the best specificity (100%). TLRKi had the best diagnostic accuracy (95.1%) and the best area under the curve (AUC) (0.990).Our study is the first one to evaluate the interest of a WBD acquisition to differentiate UP from pNETs and shows excellent diagnostic performances of the Ki approach.

MeSH terms

  • Diagnosis, Differential
  • Female
  • Humans
  • Liver / diagnostic imaging
  • Male
  • Middle Aged
  • Neuroendocrine Tumors / diagnostic imaging*
  • Octreotide / analogs & derivatives
  • Organometallic Compounds
  • Pancreas / diagnostic imaging*
  • Pancreatic Neoplasms / diagnostic imaging*
  • Positron Emission Tomography Computed Tomography* / methods
  • Prospective Studies
  • Radiopharmaceuticals
  • Sensitivity and Specificity
  • Spleen / diagnostic imaging
  • Whole Body Imaging* / methods

Substances

  • Ga(III)-DOTATOC
  • Organometallic Compounds
  • Radiopharmaceuticals
  • Octreotide