DIABETIC MACULAR EDEMA AND CATARACT SURGERY: Phacoemulsification Combined With Dexamethasone Intravitreal Implant Compared With Standard Phacoemulsification

Retina. 2021 May 1;41(5):1102-1109. doi: 10.1097/IAE.0000000000002974.

Abstract

Purpose: To compare functional and anatomical results of combined phacoemulsification and dexamethasone intravitreal implant (Ozurdex; DEX-I) with standard phacoemulsification in diabetic patients with cataract.

Methods: Retrospective, comparative, cohort study. Patients with nonproliferative diabetic retinopathy, macular edema, and cataract, treated routinely at the Eye Clinic, Azienda Ospedaliero Universitaria Policlinico, Bari, Italy with phacoemulsification associated with DEX-I (n = 23; Phaco-Dex) or standard phacoemulsification (n = 23; Phaco-alone). Best-correct visual acuity, central subfield thickness, and intraocular pressure were assessed at baseline and monthly for 3 months after surgery, and t-test was used to assess change from baseline. A multilevel regression model with an unstructured correlation-type matrix to account for repeated data measures was used for statistical analysis in and between groups.

Results: With Phaco-Dex, best-correct visual acuity increased significantly from the first month (P = 0.0005 vs. baseline) and remained stable at the following visits; central subfield thickness decreased significantly from Month 2 (P = 0.049 and P = 0.04 vs. baseline, respectively); at each timepoint, central subfield thickness was significantly lower in the Phaco-Dex group versus Phaco-alone. Intraocular pressure increased significantly during follow-up (P = 0.001 at Month 3 vs. baseline) but remained within the normal range. In the Phaco-alone group, best-correct visual acuity, and intraocular pressure did not show any significant changes after surgery, whereas central subfield thickness increased from Month 2 (P = 0.05 vs. baseline).

Conclusion: In diabetic patients with macular edema and visually significant cataract, combined treatment with phacoemulsification and DEX-I seemed to be effective, safe, and superior to standard phacoemulsification considering both functional and tomographic parameters.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Cataract / complications*
  • Cataract Extraction / methods*
  • Dexamethasone / administration & dosage*
  • Diabetic Retinopathy / complications
  • Diabetic Retinopathy / diagnosis
  • Diabetic Retinopathy / drug therapy*
  • Drug Implants
  • Female
  • Follow-Up Studies
  • Glucocorticoids / administration & dosage
  • Humans
  • Intravitreal Injections
  • Macular Edema / complications
  • Macular Edema / drug therapy*
  • Male
  • Phacoemulsification / methods*
  • Retrospective Studies
  • Tomography, Optical Coherence / methods
  • Visual Acuity*

Substances

  • Drug Implants
  • Glucocorticoids
  • Dexamethasone