Background: Due to variations and the inadequate use of personal protective equipment (PPE), this study aimed to evaluate our enhanced PPE protocols for minimizing doffing contamination.
Methods: Among 3 PPE kits (simple, Level D, and Level C), 30 participants conducted the first simulation in their adapted way and the second following enhanced protocols. After donning, participants performed a 1-minute simulation of direct care on a patient simulator covered with fluorescent powder. For tracking contamination routes between doffing processes, fluorescent powder contamination was examined with ultraviolet lamps in the darkened room.
Results: Participants were mostly registered nurses (N = 27, 90%), female (87%), and on average 31.7 years old with 8.5 years of clinical experience. Among 61 total simulations, 32 had at least 1 contamination (52.5%); "Noticeable" level (40%) at the "hands-fingers" and "shirt" body areas were most frequent. For first and second simulations with identical PPE kits, compared to the first with adapted practice, the second with enhanced protocols showed a significant reduction in doffing contamination rates (72.7% vs 22.7%, P = .0009 for both Level C and D; 77.8% vs 27.8%, P = .0027 for Level D).
Conclusions: Our enhanced protocols could significantly reduce contaminations. More studies are necessary to provide safer PPE protocol options.
Keywords: Doffing; Evaluation; Fluorescent powder; Health care personnel; Safety.