Learning a Gradient Guidance for Spatially Isotropic MRI Super-Resolution Reconstruction

Med Image Comput Comput Assist Interv. 2020 Oct:12262:136-146. doi: 10.1007/978-3-030-59713-9_14. Epub 2020 Sep 29.

Abstract

In MRI practice, it is inevitable to appropriately balance between image resolution, signal-to-noise ratio (SNR), and scan time. It has been shown that super-resolution reconstruction (SRR) is effective to achieve such a balance, and has obtained better results than direct high-resolution (HR) acquisition, for certain contrasts and sequences. The focus of this work was on constructing images with spatial resolution higher than can be practically obtained by direct Fourier encoding. A novel learning approach was developed, which was able to provide an estimate of the spatial gradient prior from the low-resolution (LR) inputs for the HR reconstruction. By incorporating the anisotropic acquisition schemes, the learning model was trained over the LR images themselves only. The learned gradients were integrated as prior knowledge into a gradient-guided SRR model. A closed-form solution to the SRR model was developed to obtain the HR reconstruction. Our approach was assessed on the simulated data as well as the data acquired on a Siemens 3T MRI scanner containing 45 MRI scans from 15 subjects. The experimental results demonstrated that our approach led to superior SRR over state-of-the-art methods, and obtained better images at lower or the same cost in scan time than direct HR acquisition.

Keywords: Deep neural networks; MRI; Super-resolution.