This study analysed the effectiveness of plasma treatment on airborne bacteria and surface counts during a 14-day intervention within a four-bedded bay in an adult respiratory ward at Cork University Hospital, Ireland. One-hundred-litre air samples were collected twice daily every weekday for 4 weeks, with settle plates and surface swabs. The plasma treatment did not have an effect on airborne bacteria and fungi that was detectable by culture. However, the possibility that culture-based sampling may be insufficiently sensitive to detect an effect, or that the duration of the study was insufficient for plasma treatment to affect a complex environment, cannot be excluded.
Keywords: Air sampling; Airborne; Continuous monitoring; Environment.
Copyright © 2021 The Authors. Published by Elsevier Ltd.. All rights reserved.