Is Doppler/Dopplex ultrasonography reliable in the assessment of percutaneous ablative therapies of hepatocellular carcinoma: a prospective cross-sectional study

Eur J Gastroenterol Hepatol. 2021 Dec 1;33(1S Suppl 1):e183-e190. doi: 10.1097/MEG.0000000000001997.

Abstract

Introduction: After hepatocellular carcinoma (HCC) interventional therapies, noninvasive vascular diagnostic imaging [duplex, Color/power Doppler ultrasonography, and triphasic computed tomography (CT)] determines the lesion complete/incomplete ablation. The aim was to analyze the usefulness of duplex, color/power Doppler ultrasonography in HCC ablation after percutaneous ablative therapies (PATs).

Methods: We included 30 patients with 33 HCCs subjected to duplex/Doppler ultrasonography, ultrasound-guided fine-needle aspiration cytology (FNAC), and triphasic CT, all these before and after PATs.

Results: One week after treatment ended, out of 21 lesions with pretreatment positive color-Doppler, signals disappeared in 19 (90.5%) lesions. Out of 29 lesions with pretreatment positive power-Doppler, signals disappeared in 24 (82.8%). Out of 13 lesions with pretreatment intralesional power/duplex arterial signals, signals disappeared in eight (61.5%). There was a significant correlation (P < 0.05) between power-Doppler arterial signals and FNAC. Before HCC ablation, power-Doppler demonstrated a sensitivity 40% and specificity 96% in HCC detection in relation to FNAC, it had a sensitivity 60% and specificity 85% in HCC detection compared to triphasic CT. After HCC ablation, power-Doppler had a sensitivity and specificity of 100% in viable malignancy detection in relation to FNAC. Power-Doppler had a sensitivity 89% and specificity 93% in residual malignancy detection in relation to triphasic CT.

Conclusion: Power-Doppler is a good positive test as intralesional arterial signals in a cirrhotic liver lesion is highly suggestive of HCC. Power-Doppler was sensitive in HCC ablation assessment in pretreatment positive cases only. Both triphasic CT and duplex/Doppler are complementary and the use of different diagnostic modalities after ablation is mandatory.

MeSH terms

  • Carcinoma, Hepatocellular* / diagnostic imaging
  • Carcinoma, Hepatocellular* / surgery
  • Contrast Media
  • Cross-Sectional Studies
  • Humans
  • Liver Neoplasms* / diagnostic imaging
  • Liver Neoplasms* / surgery
  • Prospective Studies
  • Ultrasonography
  • Ultrasonography, Doppler / methods
  • Ultrasonography, Doppler, Color / methods

Substances

  • Contrast Media