Vision before and after scharioth macular lens implantation in patients with AMD: an electrophysiological study

Doc Ophthalmol. 2021 Aug;143(1):17-31. doi: 10.1007/s10633-020-09814-8. Epub 2021 Jan 3.

Abstract

Background: For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a "Scharioth macula lens" (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens).

Methods: Fourteen patients (5 M, 9 F, 63-87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity.

Results: Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs.

Conclusion: SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.

Keywords: Age-related macular degeneration; Maculopathy; Motion-onset VEPs; Oddball ERPs; P3b; Pattern-reversal VEPs; Scharioth macular lens.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Electroretinography
  • Humans
  • Lens Implantation, Intraocular
  • Lenses, Intraocular*
  • Macular Degeneration*
  • Visual Acuity