Feasibility of stereo electroencephalogram (SEEG) with little to no scalp bone; a case report

Epilepsy Behav Rep. 2020 Oct 17:15:100394. doi: 10.1016/j.ebr.2020.100394. eCollection 2021.

Abstract

Stereo electroencephalogram (SEEG) electrode placement with cranially fixed guide bolts is recognized as one of the most accurate and safest implantation strategies to sample deep and buried cortex during certain clinical scenarios involving epilepsy surgery. Bone thickness of less than 2 mm is a relative contraindication to SEEG. Here, we describe a case drug-resistant focal epilepsy where prior craniotomies, infections and radiation therapy yielded limited skull bone requiring invasive EEG monitoring. Due to the inability to use bolts over areas with limited skull bone, we successfully utilized a combination of the standard and a modified SEEG techniques for implantation and stabilization of intracranial electrodes without complications. This strategy enabled optimal intracranial EEG monitoring and surgical management of the patient's drug-resistant focal seizures.

Keywords: Anchor bolts; Limited or absent bone; Recurrent seizures; SEEG.