Lateral Axillary Exposure for Antegrade Access during Endovascular Repair of Complex Abdominal Aortic and Thoracoabdominal Aneurysms

Ann Vasc Surg. 2021 Jul:74:176-181. doi: 10.1016/j.avsg.2020.12.029. Epub 2021 Feb 5.

Abstract

Background: During endovascular treatment of pararenal aortic aneurysms (PAA) and thoracoabdominal aortic aneurysms (TAAA), our antegrade vascular access of choice is a lateral axillary exposure (LAE). We directly access the axillary artery with multiple sheaths followed by primary closure of the axillary artery at case completion. The aim of this study is to describe our technique and to report our results with this approach.

Methods: This study is a single-institution, retrospective review of 53 patients who were treated with parallel grafts for endovascular repair of PAA and TAAA from 2006 to 2018. The aortic repairs requiring LAE included: 9 cases of endo-leaks from prior endovascular repair, 20 TAAAs, and 24 PAAs. The axillary artery was exposed with a vertical axillary skin incision followed by retraction of the lateral border of the pectoralis major to expose the axillary artery distal to the pectoralis minor. A 5-French (F) through 12F sheaths were used to directly access the axillary artery for delivery of endovascular devices.

Results: Two hundred and sixty reno-visceral stents were delivered through 125 axillary sheaths in an antegrade fashion to 114 arteries without intraoperative complications or technical failures. Two postoperative complications included an access-site hematoma managed conservatively (1.9%) and a left brachial vein thrombosis treated with anticoagulation (1.9%). There were no cases of cerebrovascular or peripheral neurologic events, upper extremity ischemia, or reoperation related to LAE.

Conclusions: LAE is a valid approach for upper extremity access during the endovascular repair of complex aortic aneurysms requiring simultaneous delivery of multiple reno-visceral devices. It does not require the use of a prosthetic conduit. There were no neurologic events or upper extremity ischemia in our series.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery*
  • Axillary Artery*
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Catheterization, Peripheral* / adverse effects
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / etiology
  • Prosthesis Design
  • Punctures
  • Retrospective Studies
  • Stents
  • Time Factors
  • Treatment Outcome