Cardiac conduction abnormalities in patients with degenerated bioprostheses undergoing transcatheter aortic valve-in-valve implantations and their impact on long-term outcomes

Int J Cardiol. 2021 May 1:330:16-22. doi: 10.1016/j.ijcard.2021.02.029. Epub 2021 Feb 14.

Abstract

Background: The relationship between preoperative cardiac conduction abnormalities (CCA) and long-term outcomes after transcatheter aortic valve-in-valve implantation (TAVI-VIV) remains unclear. The aim of the study was to evaluate the effects of preoperative CCA on mortality and morbidity after TAVI-VIV and to estimate the impact of new-onset CCA on postoperative outcomes.

Methods: Between 2011 and 2020, 201 patients with degenerated aortic bioprostheses were qualified for TAVI-VIV procedures in two German heart centers. Cases with previously implanted permanent rhythm-controlling devices were excluded (n = 53). A total of 148 subjects met the eligibility criteria and were divided into 2 study groups according to the presence of preexisting CCA (CCA (n = 84) and non-CCA (n = 64), respectively). Early and late mortality and morbidity were evaluated. Follow-up functional status was assessed according to New York Heart Association (NYHA) classification.

Results: There were no procedural deaths. TAVI-VIV related new-onset CCAs were observed in 35.8% patients. The 30-day permanent pacemaker implantation rate was 1.6% in non-CCA vs 9.5% in CCA group (p = 0.045). Preexisting right bundle-branch block (OR:5.01; 95%CI, 1.05-23.84) and first-degree atrioventricular block (OR:4.55; 95%CI, 1.10-18.73) were independent predictors of new pacemaker implantation. One-year and five-year probability of survival were comparable in CCA and non-CCA groups: 90.3% vs 91.8% and 68.2% vs 74.3%, respectively. Surviving patients with preexisting and new-onset CCA had a worse functional status according to NYHA classification at follow-up.

Conclusion: Preexisting and new-onset postoperative CCAs did not affect early and late mortality after TAVI-VIV procedures, however, they may have a negative impact on late functional status.

Keywords: Aortic valve; Conduction disturbances; Degenerated bioprosthesis; Outcomes; Transcatheter aortic valve-in-valve implantation.

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Bioprosthesis* / adverse effects
  • Heart Valve Prosthesis* / adverse effects
  • Humans
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome