Effect of thoracoabdominal aortic aneurysm extent on outcomes in patients undergoing fenestrated/branched endovascular aneurysm repair

J Vasc Surg. 2021 Sep;74(3):833-842.e2. doi: 10.1016/j.jvs.2021.01.062. Epub 2021 Feb 19.

Abstract

Objective: The outcomes after open repair of thoracoabdominal aneurysms (TAAAs) have been definitively demonstrated to worsen as the TAAA extent increases. However, the effect of TAAA extent on fenestrated/branched endovascular aneurysm repair (F/BEVAR) outcomes is unclear. We investigated the differences in outcomes of F/BEVAR according to the TAAA extent.

Methods: We reviewed a single-institution, prospectively maintained database of all F/BEVAR procedures performed in an institutional review board-approved registry and/or physician-sponsored Food and Drug Administration investigational device exemption trial (trial no. G130210). The patients were stratified into two groups: group 1, extensive (extent 1-3) TAAAs; and group 2, nonextensive (juxtarenal, pararenal, and extent 4-5) TAAAs. The perioperative outcomes were compared using the χ2 test. Kaplan-Meier analysis of 3-year survival, target artery patency, reintervention, type I or III endoleak, and branch instability (type Ic or III endoleak, loss of branch patency, target vessel stenosis >50%) was performed. Cox proportional hazards modeling was used to assess the independent effect of extensive TAAA on 1-year mortality.

Results: During the study period, 299 F/BEVAR procedures were performed for 87 extensive TAAAs (29%) and 212 nonextensive TAAAs (71%). Most repairs had used company-manufactured, custom-made devices (n = 241; 81%). Between the two groups, no perioperative differences were observed in myocardial infarction, stroke, acute kidney injury, dialysis, target artery occlusion, access site complication, or type I or III endoleak (P > .05 for all). The incidence of perioperative paraparesis was greater in the extensive TAAA group (8.1% vs 0.5%; P = .001). However, the incidence of long-term paralysis was equivalent (2.3% vs 0.5%; P = .20), with nearly all patients with paraparesis regaining ambulatory function. On Kaplan-Meier analysis, no differences in survival, target artery patency, or freedom from reintervention were observed at 3 years (P > .05 for all). Freedom from type I or III endoleak (P < .01) and freedom from branch instability (P < .01) were significantly worse in the extensive TAAA group. Cox proportional hazards modeling demonstrated that F/BEVAR for extensive TAAA was not associated with 1-year mortality (hazard ratio, 1.71; 95% confidence interval, 0.91-3.52; P = .13).

Conclusions: Unlike open TAAA repair, the F/BEVAR outcomes were similar for extensive and nonextensive TAAAs. The differences in perioperative paraparesis, branch instability, and type I or III endoleak likely resulted from the increasing length of aortic coverage and number of target arteries involved. These findings suggest that high-volume centers performing F/BEVAR should expect comparable outcomes for extensive and nonextensive TAAA repair.

Keywords: Branched EVAR; Fenestrated EVAR; Juxtarenal aneurysm; Pararenal aneurysm; Thoracoabdominal aortic aneurysm.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / mortality
  • Aortic Aneurysm, Thoracic / surgery*
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis Implantation* / mortality
  • Endoleak / etiology
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Endovascular Procedures* / mortality
  • Female
  • Graft Occlusion, Vascular / etiology
  • Humans
  • Male
  • Middle Aged
  • Paraparesis / etiology
  • Prosthesis Design
  • Registries
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stents
  • Time Factors
  • Treatment Outcome
  • Vascular Patency