Flat-Tunnel Technique With Independently Tensioned Bundles Better Restores Rotational Stability Than Round-Tunnel Technique in Anatomic Anterior Cruciate Ligament Reconstruction Using Hamstring Graft: A Cadaveric Biomechanical Study

Arthroscopy. 2022 Mar;38(3):850-859.e2. doi: 10.1016/j.arthro.2021.05.030. Epub 2021 May 27.

Abstract

Purpose: To investigate the kinematics differences between round-tunnel (ROT) and flat-tunnel (FLT) techniques in anterior cruciate ligament (ACL) reconstruction when using hamstring graft.

Methods: Nine matched pairs of fresh-frozen cadaveric knees were evaluated for the kinematics of intact, ACL-sectioned, and either ROT or FLT reconstructed knees. The graft bundles for FLT technique were separately tensioned. A 6 degrees of freedom robotic system was used to assess knee laxity: (1) 134-N anterior tibial load at 0°, 15°, 30°, 60°, and 90°of knee flexion; (2) 10 Nm of valgus torque followed by 5 Nm of internal rotation torque simulates a pivot-shift test at 15° and 30°; (3) 5-Nm internal and external rotation torques at 0°, 15°, 30°, 60°, and 90°; (4) 10-Nm varus and valgus torques at 15° and 30°.

Results: Significant differences were found for ROT versus FLT techniques in terms of the simulated pivot-shift test at 15° (2.5 mm vs 1.4 mm, respectively, difference from intact; P =.039) and the internal rotation test at 15° (2.5° vs 0.5°, respectively, difference from intact; P =.034) and 30° (2.0° vs 0.4°, respectively, difference from intact; P =.014). No significant differences were found between groups during 134-N anterior tibial load, external rotation and valgus/varus rotation. Neither technique was able to reproduce the intact state during an anterior tibial load and simulated pivot-shift test.

Conclusions: The FLT technique with independently tensioned bundles shows the same anterior control as the ROT technique but better restores rotational stability in terms of the simulated pivot-shift test and the internal rotation test in anatomic ACL reconstruction at time zero.

Clinical relevance: The FLT technique with independently tensioned bundles of ACL reconstruction appears to be a viable, more anatomic technique than the ROT technique in mimicking flat anatomy and rotational stability of native ACL.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anterior Cruciate Ligament / surgery
  • Anterior Cruciate Ligament Injuries* / surgery
  • Anterior Cruciate Ligament Reconstruction* / methods
  • Biomechanical Phenomena
  • Cadaver
  • Humans
  • Joint Instability* / surgery
  • Knee Joint / surgery
  • Range of Motion, Articular