Transverse aortic constriction (TAC) has been widely used to study cardiac hypertrophy, fibrosis, diastolic dysfunction, and heart failure in rodents. Few studies have been reported in preclinical animal models. The similar physiology and anatomy between non-human primates (NHPs) and humans make NHPs valuable models for disease modeling and testing of drugs and devices. In the current study, we aimed to establish a TAC model in NHPs and characterize the structural and functional profiles of the heart after TAC. A non-absorbable suture was placed around the aorta between the brachiocephalic artery and left common carotid artery to create TAC. NHPs were divided into 2 groups according to pressure gradient (PG): the Mild Group (PG=31.01 ± 12.40 mmHg, n=3) and the Moderate Group (PG=53.00 ± 9.37 mmHg, n=4). At 4 weeks after TAC, animals in both TAC groups developed cardiac hypertrophy: enlarged myocytes and increased wall thickness of the left ventricular (LV) anterior wall. Although both TAC groups had normal systolic function that was similar to a Sham Group, the Moderate Group showed diastolic dysfunction that was associated with more severe cardiac fibrosis, as evidenced by a reduced A wave velocity, large E wave velocity/A wave velocity ratio, and short isovolumic relaxation time corrected by heart rate. Furthermore, no LV arrhythmia was observed in either animal group after TAC. A diastolic dysfunction model with cardiac hypertrophy and fibrosis was successfully developed in NHPs.
Keywords: diastolic dysfunction; fibrosis; hypertrophy; transverse aortic constriction.