In this study, we developed a real-time quantitative polymerase chain reaction (qPCR) assay based on a dual-labeled hydrolysis probe to simultaneously detect both duck circovirus (DuCV) 1 and DuCV-2. The reproducibility, sensitivity and specificity of the primer set and probe were evaluated using other duck pathogens. The detection limit was 20 copies per µL. The intra-assay coefficients of variation (CVs) were ≤ 0.73% and the inter-assay CVs were ≤ 1.89%. No cross-reaction occurred with other duck pathogens. In addition, the qPCR assay was successfully applied to the simultaneous detection of DuCV-1 and DuCV-2 in clinical field samples. Therefore, this assay will be useful for laboratory diagnosis and epidemiological field studies of DuCV.
Keywords: Dual-labeled hydrolysis probe; Duck circovirus; Field samples; Real-time quantitative PCR; Simultaneous detection.
© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.