Objectives: Monitoring is essential to safe anticoagulation prescribing and requires close collaboration among pathologists, clinicians, and pharmacists.
Methods: We describe our experience in the evolving strategy for laboratory testing of unfractionated heparin (UFH).
Results: An intrainstitutional investigation revealed significant discordance between activated partial thromboplastin time (aPTT) and antifactor Xa (anti-Xa) assays, prompting a transition from the former to the latter in 2013. With the increasing use of oral factor Xa inhibitors (eg, apixaban, rivaroxaban, edoxaban, betrixaban), which interfere with the anti-Xa assay, we adapted our protocol again to incorporate aPTT in patients admitted on oral Xa inhibitors who require transition to UFH.
Conclusions: Our experience demonstrates key challenges in anticoagulation and highlights the importance of clinical pathologists in helping health systems adapt to the changing anticoagulation landscape.
Keywords: Anticoagulation; Direct oral anticoagulants; Heparin.
© American Society for Clinical Pathology, 2021. All rights reserved. For permissions, please e-mail: [email protected].