Background: The role of the environment in hospital acquired infections is well established. We examined the impact on the infection rate for hospital onset Clostridioides difficile (HO-CDI) of an environmental hygiene intervention in 48 hospitals over a 5 year period using a pulsed xenon ultraviolet (PX-UV) disinfection system.
Methods: Utilization data was collected directly from the automated PX-UV system and uploaded in real time to a database. HO-CDI data was provided by each facility. Data was analyzed at the unit level to determine compliance to disinfection protocols. Final data set included 5 years of data aggregated to the facility level, resulting in a dataset of 48 hospitals and a date range of January 2015-December 2019. Negative binomial regression was used with an offset on patient days to convert infection count data and assess HO-CDI rates vs. intervention compliance rate, total successful disinfection cycles, and total rooms disinfected. The K-Nearest Neighbor (KNN) machine learning algorithm was used to compare intervention compliance and total intervention cycles to presence of infection.
Results: All regression models depict a statistically significant inverse association between the intervention and HO-CDI rates. The KNN model predicts the presence of infection (or whether an infection will be present or not) with greater than 98% accuracy when considering both intervention compliance and total intervention cycles.
Conclusions: The findings of this study indicate a strong inverse relationship between the utilization of the pulsed xenon intervention and HO-CDI rates.
Keywords: C. difficile infection; Environmental interventions; Healthcare associated infections; Pulsed xenon ultraviolet.
© 2021. The Author(s).