Background: Data on the role of aerosolized hydrogen peroxide (AHP) systems in the control of the COVID-19 pandemic are still emerging. This study provides evidence of the environmental shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the hospital environment, and the efficacy of AHP to eliminate it.
Methods: A total of 324 environmental sites (224 surfaces and 100 air samples) belonging to 54 patient rooms were contextually collected and tested for genes of SARS-CoV-2 using RT-PCR assays and Xpert® Xpress SARS-CoV-2.
Results: The SARS-CoV-2 viral genome was detected in seven sites (2.5%) of three patients' rooms, including six highly touched surfaces and one air sample. Viral shedding was directly related to the distance from the patient, with 1, 1.9, and 3.5% of samples testing positive at 3, 2, and 1 meter, respectively (P-value=0.02). None of the sites showed the viral genome following application of 6% AHP. Of note, the viral genome was detected at 2 meters of a mildly symptomatic case on a face mask in the absence of aerosol generating procedures.
Conclusion: Our data support the possible role of the hospital environment as a source of infection, and the efficacy of AHP to eliminate the virus. Further studies are needed to address the viability of the pathogen in these nosocomial sites and the cost-effectiveness of routine hospital disinfection procedures using AHP for SARS-CoV-2.
Keywords: AHP; COVID-19; SARS-CoV-2; aerosolized hydrogen peroxide; decontamination; disinfection; environmental.