Hemoglobin Wayne causing a falsely elevated hemoglobin A1c

Proc (Bayl Univ Med Cent). 2021 Oct 15;35(1):84-85. doi: 10.1080/08998280.2021.1984792. eCollection 2022.

Abstract

Hemoglobin A1c (HbA1c) is an important tool for diagnosis and management of patients with diabetes mellitus (DM). However, hemoglobin variants can interfere with laboratory assays and lead to inaccurate results. This study describes a patient who was found to have falsely elevated HbA1c values secondary to hemoglobin Wayne, a rare hemoglobin variant. Although hemoglobin Wayne is often clinically silent, falsely elevated HbA1c results could lead to unnecessary medical interventions that could cause patient harm. This variation in results highlights the importance of utilizing additional measurements such as glucose readings and evaluating for hemoglobin variants when results are discordant.

Keywords: Diabetes mellitus; hemoglobin A1c; hemoglobin Wayne; hemoglobin electrophoresis; high-performance liquid chromatography.

Publication types

  • Case Reports